OFFICIAL OEM MANUFACTURING PLANT Aksaray Erenler OSB, 40. Sok. No:8, Aksaray - Turkey | ISO 9001:2015
TURKISH PRECISION OEM • DIN 42693 & EN 50216 CERTIFIED

PRECISION DISTRIBUTION & POWER
TRANSFORMER ACCESSORIES

Official export desk for İnci Transformatör Aksesuarları San. ve Tic. A.Ş. Certified manufacturer of off-circuit tap changers (30A to 1,250A), bimetallic dial thermometers, hermetic multi-function protection relays (DMCR), magnetic oil level indicators, and high/low voltage porcelain bushings. Shipped worldwide from Aksaray Erenler OSB, Turkey.

Download 2026 PDF Catalog (3.0 MB)

7,800 m²

Aksaray Enclosed Plant

1,250 A

Tap Changer Max Rating

100% FAT

Helium Leak & Voltage Tested

40+ COUNTRIES

Worldwide Transformer OEM Export
Inci Transfo Off-Circuit Tap Changer DIN 42693
DIN 42693 / EN 50216-4
MANUFACTURED IN STRICT ACCORDANCE WITH EUROPEAN STANDARDS
EN 50216-4 TAP CHANGERS
EN 50216-11 THERMOMETERS
EN 50216-3 HERMETIC RELAYS
DIN 42531 PORCELAIN BUSHINGS
DIN 42562 AIR BREATHERS
ISO 9001:2015 TUV NORD

8 CERTIFIED TRANSFORMER ACCESSORY LINES

Precision-machined from Cu-ETP electrolytic copper, CW617N forged brass, and aluminous porcelain. Supplied directly to major European, Turkish, and Middle Eastern transformer manufacturers.

Off-Circuit Tap Changers DIN 42693
DIN 42693 / EN 50216-4

Off-Circuit Tap Changers

Current: 30A to 1,250A | 10–36 kV

Linear, Delta, and Star arrangements with 3, 5, or 7 positions. Cu-ETP silver-plated contacts ensuring contact resistance < 50 µΩ under oil.

Voltage Class:10 kV, 24 kV, 36 kV
Rated Current:30A – 1250A
Positions:3, 5, 7, 9 Steps
Operating Handle:Padlockable Aluminum
WhatsApp
Bimetallic Dial Thermometers EN 50216-11
EN 50216-11

Bimetallic Dial Thermometers

Range: 0°C to +120°C | 1 or 2 Contacts

Direct-reading dial thermometer with resettable maximum temperature pointer. Equipped with 1 or 2 adjustable microswitches for Alarm & Trip protection.

Dial Diameter:80 mm / 100 mm
Contact Rating:5A 250V AC / 2A DC
Thermowell Pocket:G 1/2" or G 3/4" Brass
Protection Class:IP65 Waterproof
WhatsApp
Magnetic Oil Level Indicators DIN 42555
DIN 42555 / EN 50216-5

Magnetic Oil Level Indicators

Hermetic Magnetic Coupling | Radial Dial

Hermetically isolated magnetic drive preventing oil leaks. Radial float arm with single or dual electrical microswitch contacts for low oil level alarms.

Dial Indication:Min / Norm / Max
Coupling Type:Hermetic Magnetic Drive
Electrical Contacts:1 NO / 1 NC Switch
Ambient Range:-25°C to +115°C
WhatsApp
Pressure Relief Valves EN 50216-5
EN 50216-5 / IEC 60076

Pressure Relief Valves

Popping Pressure: 20 to 70 kPa (0.2–0.7 bar)

Immediate overpressure venting to protect transformer tanks against rupture during internal arc faults. Available with directional exhaust cowl and visual pin.

Setting Pressures:30, 50, 70 kPa Calibrated
Contact Microswitch:Optional 1 SPDT (IP65)
Body Material:Corrosion-Resistant Al
Gasket Material:Viton / NBR Oil-Proof
WhatsApp
Hermetic Protection Relays DMCR RIS EN 50216-3
EN 50216-3 (DMCR / RIS)

Hermetic Protection Relays

4-in-1 Comprehensive Protection Relay

Integrated protection for hermetically sealed distribution transformers: Gas accumulation, tank overpressure, and dual-threshold oil temperature sensing.

Monitored Params:Gas, Pressure, Temp x2
Gas Volume Trip:100 to 200 cm³ Gas
Pressure Setting:0.20 to 0.50 bar
Enclosure:UV-Stabilized Polycarbonate
WhatsApp
Dehydrating Silica Gel Air Breathers DIN 42562
DIN 42562 / EN 50216-5

Silica Gel Air Breathers

Capacities: 0.5 kg to 5.0 kg Silica Gel

Moisture absorption system for conservator-type transformers. Features an integrated hydraulic oil seal trap preventing direct atmospheric moisture ingress.

Silica Capacities:0.5 kg, 1 kg, 2 kg, 5 kg
Chamber Material:Borosilicate Glass / PC
Flange Fitting:G 1/2", G 1", DIN Flange
Desiccant Type:Orange Indicating Silica
WhatsApp
Oil Drain & Sampling Valves DIN 42551
DIN 42551 / DIN 42568

Oil Drain & Sampling Valves

Heavy Forged CW617N Brass & Bronze

Flanged bottom drain valves with integrated syringe sampling cock for Dissolved Gas Analysis (DGA) and dielectric breakdown testing. Padlockable cap.

Flange Standards:NW22, NW31, DIN Flange
Sampling Cock:Integrated DGA Cock
Working Pressure:PN 16 (1.6 MPa)
Cap Locking:Security Wire / Padlock
WhatsApp
Porcelain Bushings DIN 42531 DIN 42530
DIN 42530 / 42531 / 42532

HV & LV Porcelain Bushings

1 kV to 36 kV | 250A to 3,150A Terminals

High-mechanical strength C120 aluminous porcelain insulators with Cu-ETP copper conducting rods, brass flags, and transformer oil-resistant gasket sets.

LV Standards:DIN 42530 (1kV 250–3150A)
HV Standards:DIN 42531/32/33 (10–36kV)
Insulator Glaze:Brown (RAL 8016) / Gray
Conducting Rod:Electrolytic Cu-ETP
WhatsApp

MATERIALS & METALLURGICAL STANDARDS

Transformer accessories operate immersed in hot dielectric mineral and synthetic ester oils for 30+ years. Every raw material at İnci Transformatör is certified with EN 10204 3.1 inspection certificates.

Cu

Cu-ETP Electrolytic Copper

CW004A grade copper with min 99.90% purity and electrical conductivity > 100% IACS. Silver-plated contacts to withstand short-circuit electromechanical stresses without welding.

Ms

CW617N Die-Forged Brass

CuZn40Pb2 high-density forged brass bodies for valves, thermowell pockets, and terminals. Zero porosity ensures absolute oil tightness even under continuous vibration and thermal cycling.

Por

C120 Aluminous Porcelain

High-grade electrical porcelain conforming to IEC 60672-3. Uniformly vitrified with high-gloss brown glaze (RAL 8016), resistant to heavy industrial pollution and coastal salt fogs.

NBR

Oil-Resistant NBR / Viton

Custom molded fluorocarbon (FKM/Viton) and nitrile (NBR) gasket sets tested against ASTM D3455 for compatibility with mineral insulating oils and Midel ester fluids.

TRANSFORMER COMPONENT SPECIFICATION SELECTOR

Select your transformer design type, voltage class, and rating to identify the standard DIN/EN accessory configuration for your bill of materials (BOM).

TRANSFORMER OPERATING PARAMETERS

RECOMMENDED BOM CONFIGURATION
Recommended Tap Changer Model
INC-TC 63A / 36kV (5-Pos)
  • Key Protection Unit: DMCR Hermetic Relay
  • Temperature Instrument: EN 50216-11 Dial (2 Contacts)
  • Dehydration Unit: Hermetic Oil Seal Cap
  • HV Bushing Standard: DIN 42531 (250A / 36kV)
  • LV Bushing Standard: DIN 42530 (1kV / 630A)

All accessories manufactured in compliance with European IEC 60076 & DIN standards.

100% ROUTINE TESTING & VERIFICATION PROTOCOL

Every accessory unit produced at our Aksaray facility undergoes mandatory routine testing prior to packaging and export shipment.

01

Helium Mass Spectrometer Leak Test

100% vacuum chamber testing for oil level indicators and hermetic relays. Validates absolute tightness with sensitivity down to 1x10⁻⁸ mbar·l/s.

02

Contact Resistance Verification

Micro-ohmmeter testing of all tap changer contact steps. Contact resistance must measure under 50 micro-ohms (µΩ) to prevent localized hotspots under oil.

03

High-Voltage Dielectric Withstand

Power frequency withstand test (50 Hz, 1 minute) applied across porcelain insulators and contacts up to 75 kV rms according to IEC 60214-1.

04

Calibrated Thermal Bath Accuracy

Bimetallic dial thermometers verified across 5 temperature points (20°C, 50°C, 80°C, 100°C, 120°C) against PT100 reference sensors (Class 1.5).

AKSARAY ERENLER OSB MANUFACTURING COMPLEX

İnci Transformatör Aksesuarları San. ve Tic. A.Ş. operates an advanced 7,800 m² enclosed production plant in the Aksaray Erenler Organized Industrial Zone. With in-house precision CNC machining centers, high-pressure aluminum die-casting cells, automated silver-plating baths, and specialized helium leak-testing laboratories.

As an approved Tier-1 OEM supplier to leading international transformer manufacturers across 40+ countries in Europe, the Middle East, North Africa, and Central Asia, we deliver contract-bound reliability, competitive Turkish manufacturing efficiency, and complete technical compliance.

7,800 m²

Enclosed Plant

ISO 9001

TÜV Certified

40+

Export Countries
Inci Transfo CNC Machining Plant Aksaray
CNC Precision Machining Center Aksaray Erenler OSB Plant
OFFICIAL TECHNICAL DOCUMENTATION

DOWNLOAD COMPLETE INCI TRANSFORMER ACCESSORIES CATALOG

Includes dimensional 2D/3D CAD drawings, contact mounting schematics, oil resistance charts, DIN standard cross-references, and order code configuration tables.

FORMAT: PDF SIZE: 3.0 MB EDITION: 2026 OFFICIAL OEM
Download Catalog PDF

AUTHORIZED EXPORT SALES DESK

Submit technical drawings, Bill of Materials (BOM), or tender requests directly to our Senior Export Desk for proforma pricing, EUR.1 movement certificates, and dispatch schedules.

ONLINE • SENIOR EXPORT DESK

Musab K.

Head of Global Export Operations
  • Direct Mobile: +90 530 651 60 06
  • Official Email: hello@kaskazada.com
  • Manufacturing Plant: Aksaray Erenler OSB, 40. Sok. No:8, Turkey
  • Response SLA: < 15 Minutes for Technical Inquiries
  • Documentation: EUR.1, Certificate of Origin (COO), FAT Reports
Chat on WhatsApp Call Direct
WhatsApp Desk